Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 113

Setting Unit Policies
www.lsi.com/channel/products
101
•
Override ECC (Continue on Source Error When Rebuilding).
Determines whether ECC errors are ignored when they are encountered
during a rebuild. (ECC errors are an indication of errors that have
occurred on a particular drive since it was last read.) When not enabled, a
rebuild will abort upon encountering an ECC error and the unit will be set
to Degraded. For details, see “Setting Overwrite ECC (Continue on
Source Error When Rebuilding)” on page 108.
•
Queuing.
Determines whether command queuing is enabled for the unit.
When enabled for drives that support it, this policy can improve
performance. For details, see “Enabling and Disabling Queuing for a
Unit” on page 110.
•
StorSave Profile.
Determines what StorSave profile is used for the unit.
Three profiles are available: Protection, Balanced, and Performance. For
details, see “Setting the StorSave Profile for a Unit” on page 111.
•
Rapid RAID Recovery.
Determines which Rapid RAID Recovery option
to use,
All
,
Rebuild
or
Disable
.
All
will apply the policy to both rebuilds
and unclean shutdowns.
Rebuild
will apply only to rebuilds. You can
switch between
All
and
Rebuild
settings, but, once Rapid RAID
Recovery is disabled for the unit, it cannot be re-enabled. For details, see
“Rapid RAID Recovery” on page 113.
Figure 57. Unit Policies on Controller Settings Page in 3DM2
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)