Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 165
Background Tasks
www.lsi.com/channel/products
153
To verify a unit through 3DM2
1
In 3DM2, choose
Management >> Maintenance
.
2
In the
Unit Maintenance
section of the Maintenance page, select the unit
you want to verify and click
Verify Unit
.
3DM2 puts the selected unit in verifying mode.
If Basic Verify is selected on the Scheduling page, the verification process
begins almost immediately. If Advanced Verify is selected, the unit will
not start actively verifying until the next scheduled time.
A
Stop Verify
link appears next to the unit on the Maintenance page. If
you need to stop the verify process, use this link. (If initialization starts
because the unit had not previously been initialized, it cannot be halted, so
no
Stop Verify
link appears.)
To verify a unit through 3BM
1
At the main 3BM screen, select the unit by highlighting it and pressing
Enter.
An asterisk appears in the left-most column to indicate that it is selected.
2
Tab
to the
Maintain Unit
button and press
Enter
.
3
On the pop-up menu, select
Verify
and press
Enter
.
Verification of the selected unit starts immediately.
Figure 73. Verifying a Unit
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)