Background Tasks

www.lsi.com/channel/products

153

To verify a unit through 3DM2

1

In 3DM2, choose

Management >> Maintenance

.

2

In the

Unit Maintenance

section of the Maintenance page, select the unit

you want to verify and click

Verify Unit

.

3DM2 puts the selected unit in verifying mode.

If Basic Verify is selected on the Scheduling page, the verification process
begins almost immediately. If Advanced Verify is selected, the unit will
not start actively verifying until the next scheduled time.

A

Stop Verify

link appears next to the unit on the Maintenance page. If

you need to stop the verify process, use this link. (If initialization starts
because the unit had not previously been initialized, it cannot be halted, so
no

Stop Verify

link appears.)

To verify a unit through 3BM

1

At the main 3BM screen, select the unit by highlighting it and pressing
Enter.

An asterisk appears in the left-most column to indicate that it is selected.

2

Tab

to the

Maintain Unit

button and press

Enter

.

3

On the pop-up menu, select

Verify

and press

Enter

.

Verification of the selected unit starts immediately.

Figure 73. Verifying a Unit