Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 96
Chapter 7. Configuring Units
84
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
Figure 40. Configuring a Unit in 3DM2
4
In the
Type
field, select the RAID configuration you want.
5
If stripe size applies to the RAID type you select, select a
Stripe Size
.
(Stripe size does not apply to RAID 1.)
6
Optional: In the
Name
box, enter a name for the unit (up to 21 characters,
including dashes and underscores).
7
If you have 12 drives attached to the controller and selected RAID 50 as
the configuration in step 3, select whether you want 3, 4, or 6 Drives Per
Subunit, as shown here.
Figure 41. Configuring a RAID 50 with 12 Drives
8
Make changes to the unit policies, as desired. You can enable or disable
the
Write Cache
,
Auto-Verify
, and
Overwrite ECC
. You can also set the
StorSave
policy, the
Rapid RAID Recovery
policy, and the
Read Cache
policy
For details about these settings, see “Setting Unit Policies” on page 100.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)