Unit information, Drive information – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 222

Chapter 11. 3DM2 Reference
210
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
Unit Information
Unit Number.
The unit number assigned to the unit by the firmware. Use the
checkbox next to the unit to select a unit before clicking one of the task
buttons.
# Drives.
Number of drives in the unit.
Type of Unit.
Type of unit: RAID 0, RAID 1, RAID 5, RAID 6, RAID 10,
RAID 50, or Single Disk. If the unit has been given a unique name, it shows
beneath the RAID type.
Name of Unit.
User-assigned unique name of the unit. The default setting is
blank.
Capacity.
The usable capacity (size) of the unit.
Status.
Operational status of the unit: Ok, Rebuilding, Initializing, Verifying,
Migrating, Degraded, or Inoperable (missing drives). When Rebuilding,
Initializing, Migrating, or Verifying, the percentage (%) complete is also
shown. The percentage complete can be active or paused. To see whether this
task is currently active or paused, click on the unit number to display the Unit
Details page, which has that information. For an explanation of the statuses,
see “Unit Statuses” on page 137.
Drive Information
VPort.
The VPort (virtual port) to which the drive is connected.
Model.
The model of the drive.
Capacity.
The capacity (size) of the drive.
Status
. The status of the drive: OK, Not Supported, Not Present, and so forth.
If you need help regarding a status displayed here, please contact Technical
Support. For more information, see “Drive Statuses” on page 138.
Remove Drive.
The
Remove Drive
link removes a drive from the controller
so that you can safely unplug it. In the Unit Maintenance section, this link is
only provided for drives that can be safely removed without creating an
inoperable unit. (For example, a RAID 5 missing 2 or more drives or a RAID
0 missing 1 or more drives would become inoperable.) If you remove a drive
from a redundant unit, the unit will become degraded. Once a unit has become
degraded, additional drives cannot be removed without making it inoperable,
so no
Remove Drive
link will display.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)