004d battery temperature is too high, 004e battery capacity test started – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 283

Error and Notification Messages
www.lsi.com/channel/products
271
004D Battery temperature is too high
Event Type
Error
Cause
The battery pack temperature being monitored by the Battery Backup Unit is
too high.
The BBU is unable to backup the 3ware RAID controller.
Action
Check for sufficient airflow around the card. To increase airflow you can:
•
Leave the PCI slots next to the controller empty
•
Add fans to your computer case
•
Move and bundle wiring that is blocking air circulation
Contact 3ware technical support at
http://www.lsi.com/channel/ContactUs
if
this problem is not due to environmental reasons or improper case cooling.
004E Battery capacity test started
Event Type
Information
Cause
A battery test was started through CLI or 3DM2.
Background Information
The test estimates how many hours the Battery Backup Unit will be able to
back up the 3ware RAID controller in case of a power failure.
This test performs a full battery charge/discharge/re-charge cycle and may
take up to 20 hours to complete. During this test the Battery Backup Unit
cannot backup the 3ware RAID controller. In addition, all units have their
write cache disabled until the test completes.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)