Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 245
Problems and Solutions
www.lsi.com/channel/products
233
•
The BIOS may have changed the order of the boot devices. Check your
system BIOS boot sequence.
•
The 3ware BIOS will only boot from the first unit listed in 3BM. You can
change the unit from which the 3ware controller boots by moving it to the
top of the list of units by highlighting the unit and pressing the 'Page Up'/
'Page Down' keys.
•
The operating system is installed on a device that is not in your system’s
boot order. Use your system’s Setup utility to include the StorSwitch
controller in the boot order.
•
If your operating system was installed before you configured your RAID
units, you may have overwritten your operating system. Remember that
creating or deleting a RAID unit overwrites any existing data on the
member drives. Reinstall your operating system.
•
There may be a compatibility problem between the motherboard system
BIOS and the 3ware BIOS. Check the LSI website to see if your
motherboard is compatible with the 3ware BIOS, and check with your
motherboard manufacturer for potential BIOS updates. Interoperability
information is available at
http://www.lsi.com/channel/support/marketing_resources/index.html
.
A unit shows up as unusable, because of missing drives:
Unusable Arrays:
3 drive 64K RAID 5 558.77 GB (Unit 1)
SATA - Maxtor 6B300S0 279.86 GB (Port 6)
The unit has some but not all of its members available.
The unit will be unusable. If this unit is your boot
device, your system will not boot. You must either
return the missing disks to complete the unit, or
release the member disks by deleting the incomplete
unit(s) listed in the display. Remember that deleting
a RAID unit overwrites any existing data on the member
drives.
CAUTION:
Do not delete the inoperable unit and recreate it, as this will
overwrite the data and make data recovery very difficult.
If you get this error, contact technical support at
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)