000e initialize failed, 000f smart threshold exceeded – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 258
Chapter 12. Troubleshooting
246
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
Action
Allow the initialization to complete. This will return the unit to its normal
redundant state.
See Also
For more information, see “About Initialization” on page 146
000E Initialize failed
Event Type
Error
Cause
The 3ware RAID controller was unable to complete the initialization. This
error can be caused by unrecoverable drive errors.
If this unit was a redundant unit, and the initialization failed because of a
problem on a particular disk drive, then the unit will be degraded.
Action
If the unit was degraded, then rebuild the unit. This may necessitate replacing
the drive.
Check physical cable and power connections. You can also run the drive
manufacturer’s diagnostic and repair utilities on the drive.
See Also
For links to drive manufacturer diagnostic utilities and troubleshooting
advice, search the LSI KnowledgeBase for keyword
“Basic Troubleshooting: Check This First” on page 228
000F SMART threshold exceeded
Event Type
Warning
Cause
SMART monitoring is predicting a potential drive failure.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)