005C Battery is weak
Event Type
Warning
Cause
The Battery Backup Unit periodically evaluates the health of the battery and
its ability to backup the 3ware RAID controller in case of a power failure.
This message is posted when the result of the health test is below the warning
threshold.
Action
Replace the battery pack if warnings persist.
005E Cache synchronization completed
Event Type
Information
Cause
The 3ware RAID controller performs cache synchronization when system
power is restored following a power failure. This message is posted for each
unit when the cache synchronization completes successfully.
You will also see this message if drive insertion causes a unit to become
operational and retained write cache data was flushed.
005F Cache synchronization failed; some data lost
Event Type
Error
Cause
The 3ware RAID controller performs cache synchronization when system
power is restored following a power failure. The cache synchronization was
not successful for some reason.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)