Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 29

Monitoring, Maintenance, and Troubleshooting Features
www.lsi.com/channel/products
17
includes a typical read-ahead caching method which is used to proactively
retrieve data from media and store it locally on the controller with the
anticipation that it may be requested by the host. By default read cache is
set to the Intelligent mode. For more information, see “Working with
Read Cache Settings” on page 104.
•
Write Cache
. You can enable or disable write cache using 3BM, 3DM2,
and CLI. When write cache is enabled, data will be stored in 3ware
controller cache and drive cache before the data is committed to disk.
This allows the system to process multiple write commands at the same
time, thus improving performance. However when data is stored in cache,
it could be lost if a power failure occurs. With a battery backup unit
(BBU) installed, the data stored on the 3ware controller can be restored.
(For more information, see “Enabling and Disabling the Unit Write
Cache” on page 102.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)