Setting the Auto-Rebuild Policy
www.lsi.com/channel/products
71
Setting the Auto-Rebuild Policy
The Auto-Rebuild policy determines how the controller firmware will attempt
to rebuild degraded units.
When Auto-Rebuild is disabled, only spares will be automatically used to
rebuild degraded units. When Auto-Rebuild is enabled, the firmware will
select drives to use for automatically rebuilding a degraded unit using the
following priority order.
•
Smallest usable spare.
•
Smallest usable unconfigured (available) drive.
•
Smallest usable failed drive.
Enabling Auto-Rebuild allows you to add a drive to the controller and have it
be available for a rebuild, without having to specify it as a spare.
With Auto-Rebuild enabled, if you accidentally disconnect a drive (causing
the controller to see it as a failed drive) and then reconnect it, the controller
will automatically try to use it again.
You can enable or disable the Auto-Rebuild policy through 3DM2 or 3BM.
To enable Auto-Rebuild through 3DM2
1
Choose
Management >> Controller Settings
from the menu bar in
3DM2.
2
In the Other Controller Settings section at the bottom of the screen, select
the
Enabled
option for
Auto-Rebuild
.
The page refreshes, and a message at the top confirms the change you
have made.
To enable Auto-Rebuild through 3BM
1
On the main 3BM screen,
Tab
to
Settings
and press
Enter
.
2
On the pop-up menu, select
Controller Policies
and press
Enter
.
3
On the Policy Settings page,
Tab
to the
Auto-Rebuild
field, press
Enter
to display the options, select
Enable
and press
Enter
again to select it.
4
Tab
to
OK
and press
Enter
to select it.
The policy is enabled immediately.
Using Auto-Carving for Multi LUN Support
Auto-carving is useful for creating multiple volumes out of large arrays at the
hardware level. Then, when you boot to the operating system, each volume
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)