Chapter 12. Troubleshooting

284

3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2

8024 Enclosure temp above operating

Event Type

Error.

Cause

Applies to 9750 and 9690SA controllers.

The enclosure temperature is above the enclosure manufacturer’s specified
operating temperature.

Action

Make sure that the fans are operational. Check for blocked ventilation in the
enclosure and the operating environment.

Continued operation of the enclosure at high temperatures may lead to data
loss and operational failure.

8025 Enclosure temp removed

Event Type

Warning.

Cause

Applies to 9750 and 9690SA controllers.

The temperature sensor in the enclosure has been removed or has failed and
the enclosure temperature is no longer being monitored.

Action

The temperature sensor should be replaced or repaired. This may require
specialized skills. Contact your enclosure manufacturer for more information.

8026 Enclosure temp added

Event Type

Information.

Cause

Applies to 9750 and 9690SA controllers.

A temperature sensor has been added to the enclosure or an existing sensor
has been plugged in. This error message can occur due to a poor connection.