Chapter 7. Configuring Units
110
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
7
When you are finished making changes, press
F8
to save them and exit
3BM.
Enabling and Disabling Queuing for a Unit
Some drives support command queuing, a feature that can result in increased
performance for applications that require a lot of random access of data
(usually server-type applications). This is accomplished by causing command
reordering to be done on the drive.
In order to make use of command queuing, the feature must be enabled at both
the drive and the controller. You can enable support for command queuing on
a per-unit basis, as described below.
You can see whether command queuing is supported and enabled for a
particular drive in the Drive Details window. For details, see “Drive Details
window” on page 197.
To enable or disable queuing for a unit through 3DM2
1
Choose
Management >> Controller Settings
from the menu bar in
3DM2.
2
In the
Unit Policies
section of the Controller Settings page, enable
queuing by checking the box under “Queuing” for the designated unit;
disable it by unchecking the box.
The page refreshes, and a message at the top confirms the change that you
have made.
To enable or disable queuing for a unit through 3BM
1
At the main 3BM screen, select the unit by highlighting it and pressing
Enter
.
An asterisk appears in the left-most column to indicate that it is selected.
2
Tab to the
Maintain Unit
button and press
Enter
.
3
On the pop-up menu, select
Configure
and press
Enter
.
4
In the
Configure Disk Array
screen,
Tab
to the field
Drive Queuing
Mode
.
5
Press
Enter
to display the choices, use the
arrow keys
to select the setting
you want (Enabled or Disabled), and press
Enter
again to choose it.
Note:
Not all drives support command queuing. If a drive does not support
command queuing, the policy setting for the controller is ignored. Queuing
information for SAS is not available.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)