beautypg.com

8030 enclosure power normal, 8031 enclosure power fail – Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 298

background image

Chapter 12. Troubleshooting

286

3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2

Action

Check the operational status of the temperature sensor. If it has failed, replace
it.

See your enclosure documentation or contact your enclosure manufacturer for
more information.

8030 Enclosure power normal

Event Type

Information.

Cause

Applies to 9750 and 9690SA controllers.

The enclosure power supply is now back within the acceptable range.

Action

None required.

8031 Enclosure power fail

Event Type

Error.

Cause

Applies to 9750 and 9690SA controllers.

One of the enclosure power supplies is not working. Either a power supply
has failed or a cord is unplugged.

Action

Reseat the power supply cord. Replace any failed power supply as soon as
possible.

It is recommended to use an uninterruptible power supply (UPS) to protect
against power failures.