beautypg.com

0049 battery temperature is normal, 004a battery temperature is low – Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 281

background image

Error and Notification Messages

www.lsi.com/channel/products

269

Action

The battery pack must be replaced.

This may be a fault in the BBU control module. If you get this error, do the
following:

1

Turn off the computer and remove the 3ware RAID controller.

2

Remove the BBU control module from the 3ware RAID controller and
the battery module from the remote card.

3

Unplug the battery from the control module.

4

Return the BBU control module and battery module to 3ware.

For more details on removing the BBU, see the installation guide that came
with your 3ware RAID controller.

0049 Battery temperature is normal

Event Type

Information

Cause

The battery pack temperature being monitored by the Battery Backup Unit
fell outside of the acceptable range and then came back within the acceptable
range.

Action

None required

004A Battery temperature is low

Event Type

Warning

Cause

The battery pack temperature being monitored by the Battery Backup Unit
has fallen below the acceptable range. The most likely cause is ambient
temperature.

Action

The Battery backup Unit is presently still able to backup the 3ware RAID
controller, but you should replace the battery pack if the temperature warning