beautypg.com

004f cache synchronization skipped, 0050 battery capacity test completed – Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 284

background image

Chapter 12. Troubleshooting

272

3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2

Action

None required.

See Also

See the Install Guide for your controller.

004F Cache synchronization skipped

Event Type

Warning

Cause

The cache synchronization that is normally performed when power is restored
after a power failure was skipped and write data is still being backed up in the
controller cache. This can occur if a unit was physically removed or became
inoperable during the power outage.

Action

Return missing drive(s) to the controller so that the missing write data can be
saved.

0050 Battery capacity test completed

Event Type

Information

Cause

The Battery Backup Unit has completed a battery capacity test.

The BBU is again able to backup the 3ware RAID controller and write cache
has been re-enabled for all units. (During the test, backup and write cache
were disabled).