Background Tasks
www.lsi.com/channel/products
149
Background Initialization After Power Failure
The 3ware controller detects and handles power failures, using a mechanism
that ensures that redundant units have consistent data and parity. When a
redundant unit is unexpectedly shutdown, there is a possibility some data and
parity may be inconsistent. If a unit or sub-unit of a redundant unit is detected
to have been shutdown uncleanly, the unit or sub-unit will change its mode to
either ‘Initializing’ or ‘Verifying.’
When the initialization is complete, the unit is guaranteed to be redundant
again. The initialization does not erase user data.
This process will take less time if the unit is created with Rapid RAID
Recovery enabled during unit creation. See “Rapid RAID Recovery” on
page 113.
About Verification
The verify feature confirms the validity of redundant data on redundant units
and performs media scans on non-redundant units.
Regular weekly verification is a good idea, as it can provide early warning of
a disk drive problem or failure. This allows you to replace drives before they
fail.
You can start a verify manually or regular verification can be done
automatically by enabling Auto-Verify. (See “Starting a Verify Manually” on
page 152 and “Using Auto Verification” on page 152.)
During verification, I/O continues normally, but with a slight performance
loss, depending on your verify rate setting. You can adjust how much
verification will slow performance by setting a rate at which it occurs. (See
No
RAID 5 with 3 or 4 disks
RAID 50 with 6, 8, or 9 disks
RAID 50 with 12 disks in 3 subunits of 4
RAID 50 with 12 disks in 4 subunits of 3
RAID 50 with 16 disks in 4 subunits of 4
Yes
RAID 5 with 5 or more disks
RAID 6
RAID 50 with subunits of 5 or more disks
Table 12: Initialization Requirements for Different RAID
Configurations (continued)
Initialization Required for
Highest Performance?
RAID Configurations
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)