Selecting advanced or basic verify schedules – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 178

Chapter 8. Maintaining Units
166
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
You can easily disable a current Rebuild/Migrate schedule without deleting
the schedule itself.
To turn on or off use of the current Migrate/Rebuild task schedule
1
Choose
Management >> Schedule
from the menu bar.
The Scheduling page appears, showing the schedule for Rebuild/Migrate
Tasks.
2
In the Schedule Rebuild Tasks section, select the appropriate setting:
Follow Schedule
or
Ignore Schedule
.
The illustration below shows this setting for the rebuild task schedule.
Selecting Advanced or Basic Verify Schedules
You cannot ignore a verify schedule. You can only select either Basic or
Advanced as the verify schedule.
The Basic verify schedule is selected by default and is scheduled to run once a
week at Friday 12 am. You can change the time at which it runs on the
Schedule page in 3DM2 or on the Policy screen in 3BM.
The Advanced verify schedule is similar to the Rebuild/Migrate schedule and
has seven scheduling slots. For details about the functioning of Basic and
Advanced verify schedules, see “Using Auto Verification” on page 152.
To select Basic or Advanced verify schedule
1
Choose
Management >> Schedule
from the menu bar.
The Scheduling page appears, showing the schedule for Rebuild/Migrate
Tasks.
Note:
When you first use 3DM2, daily schedules exist with 24 hour duration—that
is, the schedule is for “all the time.” Until you change these 24-hour daily schedule,
enabling the schedule will not have any direct effect.
Note:
Self-test schedules cannot be turned off in this way. To disable self-tests you
must either remove all schedule times, or uncheck the tests listed in the
Tasks
column. For more information, see “Selecting Self-tests to be Performed” on
page 168
.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)