beautypg.com

8044 enclosure current normal, 8045 enclosure current over – Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 302

background image

Chapter 12. Troubleshooting

290

3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2

Action

If applicable, replace the failed power supply.

Contact your enclosure manufacturer for more information.

8044 Enclosure current normal

Event Type

Information.

Cause

Applies to 9750 and 9690SA controllers.

The enclosure power supply current is now back within the acceptable range.

Action

None required.

8045 Enclosure current over

Event Type

Error.

Cause

Applies to 9750 and 9690SA controllers.

The enclosure power supply amperage is higher than normal.

Action

Replace the failing power supply or remove any extra devices. This may be
caused by too many hard drives, which have exceeded the enclosure power
specifications. See your enclosure documentation or contact your enclosure
manufacturer for more details.

Too much current cannot be corrected by a UPS, although it can provide some
protection against a power surge.