Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 120
![background image](https://www.manualsdir.com/files/864341/content/doc120.png)
Chapter 7. Configuring Units
108
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
To enable or disable the Auto-Verify policy for an existing unit
through 3DM2
1
Choose
Management >> Controller Settings
from the menu bar.
2
In the
Unit Policies
section of the
Controller Settings
page check the
Auto-Verify
box for the appropriate unit. (To disable this policy, uncheck
the box.)
The page refreshes, and a message at the top confirms the change you
have made.
To enable or disable the Auto-Verify policy for an existing unit
through 3BM
1
At the main 3BM screen, select the unit by highlighting it and pressing
Enter
.
An asterisk appears in the left-most column to indicate that it is selected.
2
Tab to the
Maintain Unit
button and press
Enter
.
3
On the pop-up menu, select
Configure
and press
Enter
.
4
In the
Configure Disk Array
screen,
Tab
to the field
Auto-Verify
.
5
After completing any other changes you wish to make, tab to
OK
and
press
Enter
.
Setting Overwrite ECC (Continue on Source Error
When Rebuilding)
The
Overwrite ECC (Continue on Source Error When Rebuilding)
policy
is available for units which are redundant. (For units which are not redundant,
this option is not shown on the screen.) When this policy is set, ECC (Error
Correcting Code) errors are ignored when they are encountered during a
rebuild. (ECC errors are typically defects that have been detected in the drive
since initialization.) When this policy is not set, if a unit is rebuilding, the
rebuild will abort when it encounters an ECC error and the unit will be set
back to Degraded.
Since enabling this policy could result in the loss of some source data in the
event of source errors, the default is to not enable this policy. Select this
option only if you want to ensure that a rebuild will complete successfully
without manual intervention. If the rebuild fails and
Overwrite ECC
(Continue on Source Error When Rebuilding)
is not selected, then you
have the option to start another rebuild manually. After completing a rebuild
with this policy enabled, it is recommended that you execute a file system
check when the rebuild completes.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)