Unit statuses – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 149
Checking Unit and Drive Status through 3DM2
www.lsi.com/channel/products
137
Unit Statuses
The following is a list of unit statuses you may see in 3DM2:
•
OK.
The unit is optimal and is functioning normally.
•
Rebuilding.
The unit is in the process of writing data to a newly added
disk in a redundant unit, in order to restore the unit to an optimal state.
The unit is not fully fault tolerant until the rebuilding is complete. For
more information, see “To verify a unit through 3BM” on page 153.
•
Rebuild-Paused.
The unit is set to rebuild, however scheduling is
enabled, and the present time is not during a scheduled timeslot.
Rebuilding will start at the next scheduled time slot. Rebuilds are also
paused for up to ten minutes after a reboot, even during a scheduled
timeslot.
•
Initializing.
The unit is in the process of writing to all of the disks in the
unit in order to make the array fault tolerant. For more information, see
“About Initialization” on page 146.
•
Initializing-Paused.
The unit is set to initialize, however scheduling is
enabled and the present time is not during a scheduled timeslot.
Initializing will start at the next scheduled time slot. Initializations follow
the Rebuild/Migrate task schedule. Initialization is also paused for up to
ten minutes after a reboot, even during a scheduled timeslot.
•
Verifying.
The unit is in the process of ensuring that the parity data of a
redundant unit is valid. For more information, see “About Verification”
on page 149.
•
Verify-Paused.
The unit is set to verify, however, scheduling is enabled,
and the present time is not during a scheduled timeslot. Verification will
start at the next scheduled time slot.
•
Migrating.
The unit is in the process of being reconfigured while it is
online. Migration can be used to change the RAID level, to expand the
capacity by adding additional drives, or to change the stripe size. For
more information, see “Changing An Existing Configuration by
Migrating” on page 115.
Solid red
Drive fault
This drive has failed. You should replace it and rebuild the unit.
Blinking red
Predicted drive fault
3ware software predicts that this drive will fail soon. You may
want to replace it.
Table 11: Meaning of LED Colors and Behavior (continued)
Color
Drive Status
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)