0065 local link down, 0066 reverted to emergency recovery firmware, 0070 drive write fault; some data lost – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 290

Chapter 12. Troubleshooting
278
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
0065 Local link down
Event Type
Warning.
Cause
Applies to 9750 and 9690SA controllers.
A cable has been unplugged, removing a link to a controller phy.
0066 Reverted to emergency recovery firmware
Event Type
Information.
Cause
The main firmware image is corrupted because the firmware upgrade was
interrupted by a power failure, or the firmware update was not able to
successfully complete.
Action
Retry the firmware update; if not successful, call technical support.
0070 Drive write fault; some data lost
Event Type
Error.
Cause
A SAS or SATA drive reported this error asynchronously. Some data loss
might have occurred if you are using StorSave Performance mode.
Action
Recommend replacing the drive that reported this error.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)