Unit names, Other controller settings – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 215

Controller Settings page
www.lsi.com/channel/products
203
Queuing.
(Not applicable for SAS drives) This policy enables or disables
Native Command Queuing (NCQ) for SATA drives in the unit. By default,
queuing is disabled. You can enable it, if desired.
NCQ only operates when the feature is enabled at both the drive and the
controller. If a drive does not support NCQ, the policy setting for the
controller is ignored.
Enabling NCQ can improve performance in many applications; it causes
command reordering to be done on the drive itself.
StorSave Profile.
The StorSave feature includes an option that lets you
change the StorSave Profile used for a unit. Three profiles are available:
Protection, Balanced, and Performance. These profiles automatically adjust
several different factors that affect protection and performance, including
whether FUA (Forced Unit Access) is honored, whether Write Journaling is
enabled, and whether Disable Cache on Degrade is enabled. For additional
information, see “Setting the StorSave Profile for a Unit” on page 111.
Rapid RAID Recovery.
Determines which Rapid RAID Recovery option to
use,
All
,
Rebuild
or
Disable
.
All
will apply the policy to both rebuilds and
unclean shutdowns.
Rebuild
will apply only to rebuilds. You can switch
between
All
and
Rebuild
settings. However, once Rapid RAID Recovery is
disabled for the unit, it cannot be re-enabled. For additional information, see
“Rapid RAID Recovery” on page 113.
Unit Names
Units can be assigned names. A name can be assigned when the unit is created
and can be changed from this screen. For additional information, see “Naming
a Unit” on page 99.
Other Controller Settings
The Other Controller settings displays information about additional settings,
some of which can only be changed in the BIOS (3BM) or CLI. 3BM is not
available for Mac users.
Auto-Rebuild.
The Auto-Rebuild policy determines how the controller
firmware will attempt to rebuild degraded units.
When Auto-Rebuild is disabled, only spares will be used to automatically
rebuild degraded units. When Auto-Rebuild is enabled, the firmware will
Note:
If the write cache setting is disabled for a unit, the StorSave Profile capability
does not apply and is automatically disabled.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)