Chapter 8. Maintaining Units
148
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
initialized. These RAID types are fully redundant, regardless of whether or
not they are initialized. Similarly, RAID 50 units with a grouping of 3 or 4
disks in a subunit do not need to be initialized. However, RAID 50 with a
grouping of 5 or more disks in a subunit do need to be initialized for full
performance.
Initialization of RAID 1 and RAID 10 Units
RAID 1 and RAID 10 units do not need to be initialized when they are
created. They are fault tolerant and are immediately available for use with full
performance when created.
Initialization of RAID 1 or RAID 10 units will take place automatically the
first time the unit is verified.
Initialization of a RAID 1 unit results in data from one disk (the disk on the
lower port number) being copied to the other disk. In RAID 10 units, data
from one half of the unit is copied to the other half.
After the initialization, subsequent verifies to a RAID 1 or RAID 10 unit
check for data consistency by comparing the data from one drive (or set of
drives) to the other drive (or set of drives).
Notes:
For RAID 5 and RAID 6 with more 5 or more drives, it is strongly required that you
initialize the unit. Initialization is critical to insuring data integrity on the unit. The
initialization can be a background or foreground initialization.
For RAID 5 with 3 or 4 drives, initialization before use is not required. However,
initialization is required before a unit can be verified. Consequently, if you attempt to
verify a RAID 5 with 3 or 4 drives that has not yet been initialized, you will see a
message that the array has not been initialized, and initialization will begin. This is
considered part of the normal operation of the unit.
Table 12: Initialization Requirements for Different RAID
Configurations
Initialization Required for
Highest Performance?
RAID Configurations
No
Single drive
No
RAID 0
No
RAID 1
RAID 10
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)