beautypg.com

Problems and solutions, Enclosure-related problems – Avago Technologies 3ware SAS 9750-16i4e User Manual

Page 243

background image

Problems and Solutions

www.lsi.com/channel/products

231

commands with FUA (Force Unit Access), flush commands, and a
drive sectors's read, write, and write commands with FUA.
(/cx/px show dpmstat type=ext)

Clear Individual Statistic Counters.

On a per-port basis, you can clear

specific statistic counters, using these commands:

/cxpx set dpmstat=clear

/cxpx set dpmstat=clear type=ra

/cxpx set dpmstat=clear type=lct

/cxpx set dpmstat=clear type=ext

Problems and Solutions

This section covers some common problems and solutions. It is organized into
the following sections:

Enclosure-Related Problems

An LED is blinking red on an enclosure.

Hardware Installation Problems

The 3ware BIOS screen never appears

Need to boot from a non-3ware device without changing the boot
order

Software Installation Problems

The 3ware RAID controller was configured without problems, but the
system does not boot

A unit shows up as unusable, because of missing drives:

Problems in 3DM2 and 3BM

A 3ware RAID controller does not show in the list of controllers

When booting a system, a drive is not showing up in the startup
screens, in 3BM, or in 3DM2

Enclosure-Related Problems

An LED is blinking red on an enclosure.

A blinking red LED on an enclosure may indicate that there is a “predicted
fault” on the drive in that slot. Actual LED behavior will depend on the
enclosure manufacturer. Refer to the user guide for your enclosure.

Such an error can result from a number of different factors, including a
SMART error, read error, or cable error. The drive has not failed yet, but may
fail soon.