Removing a drive – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 142
![background image](https://www.manualsdir.com/files/864341/content/doc142.png)
Chapter 7. Configuring Units
130
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
To add a drive
1
Insert the drive into the hot swap bay or into your enclosure.
For details, refer to the documentation for your enclosure.
2
In 3DM2, choose
Management >> Maintenance
.
3
On the Maintenance page, click
Rescan Controller
.
The drive will appear in the list of available drives. You can now use it in
a new RAID configuration, as part of an existing configuration, or as a
replacement drive in the event that another drive degrades.
If you want to use this drive as a spare, see “Creating a Hot Spare” on
page 97.
Removing a Drive
If you have hot swappable drives in a carrier or an enclosure and you want to
physically remove a drive from your system without powering it down, you
should first remove it through the 3ware software.
Follow this procedure if you know that a drive is developing a problem and
you want to replace it, or to replace a drive which has already failed.
To remove a drive
1
In 3DM2, choose
Management >> Maintenance
.
On the Maintenance page,
Remove Drive
links appear next to all drives
that can be removed from units, and next to drives in the Available Drives
list.
Warnings:
Physically removing a drive that is not in a hot swap bay or that is part of a non-
redundant unit, can result in a system hang or may even damage the system and
the drive.
The steps below will destroy any information that identifies this drive as part of a
RAID unit.
Existing data on this drive will no longer be available.
Notes:
If you want to remove a unit from your system and reassemble it in another system,
do not follow these steps. Instead, turn to “Removing a Unit” on page 125.
If you physically remove a drive on a controller without first removing it in 3DM2, it
will be listed as removed, however it will not be completely removed unless you
Rescan the controller.
Drives that are part of a non-redundant or degraded unit cannot be removed.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)