Setting the storsave profile through 3bm, Rapid raid recovery – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 125

Setting Unit Policies
www.lsi.com/channel/products
113
Setting the StorSave Profile through 3BM
In 3BM, the StorSave Profile is set on the
Configure Disk Array
screen.
To set the StorSave Profile through 3BM
1
At the main 3BM screen, select the unit by highlighting it and pressing
Enter
.
An asterisk appears in the left-most column to indicate that it is selected.
2
Tab to the
Maintain Unit
button and press
Enter
.
3
On the pop-up menu, select
Configure
and press
Enter
.
4
In the
Configure Disk Array
screen,
Tab
to the field
StorSave Profile
.
The current setting—Protection, Balanced, or Performance—is shown.
(The default setting is Balanced.)
5
Press
Enter
to display the choices, use the
arrow keys
to select the
setting you want, and press
Enter
again to choose it.
6
Tab
to the
OK
button and press
Enter
to select it.
You return to the main 3BM screen.
7
When you are finished making changes, press
F8
to save them and exit
3BM.
Rapid RAID Recovery
The Rapid Raid Recovery feature increases the speed with which a redundant
unit can be made redundant again when a rebuild is required. It can also
increase the speed of verification or initialization that may occur in the event
of an unclean shutdown.
Rapid RAID Recovery is possible because the firmware maps the unit, and
tracks the areas of the unit where write activity occurs. Then, if a rebuild,
initialization, or verify is required, the controller only has to address the active
areas. The fewer active areas, the faster the rebuild, initialize or verify.
Since the units are mapped out and tracked from the creation of the unit, this
feature can only be enabled during unit creation. Also, once disabled, it
cannot be re-enabled.
The more space is available on a unit, the more benefit you will see in the
event of a rebuild, if you enable Rapid RAID Recovery. If all of a unit’s
capacity is being used, you may not see reduction of rebuild speed when using
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)