Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 33

Basic Steps for Creating a Unit
www.lsi.com/channel/products
21
3
Make sure that the proper drives are listed.
Figure 12. Create Disk Array screen
To name the unit and select the desired RAID configuration
1
(Optional) Press Enter in the Array Name field and type a name for the
unit. Then press Enter again to accept the name.
2
Use the arrow keys or press Tab to move to the RAID Configuration
field and press Enter to view the available RAID levels for the number of
drives you selected.
Figure 13. List of Configuration Choices for Four Drives
3
Use the arrow keys to highlight the desired RAID configuration and
press Enter.
For information about the different RAID levels and when to use each,
see “Understanding RAID Concepts and Levels” on page 5.
4
Use the arrow keys or press Tab to move to the field Stripe Size and
select the desired stripe size (16KB, 64KB, or 256KB).
Notes:
Striping size is not applicable for RAID 1, because it is a mirrored unit
without striping.
For RAID 6, only stripe sizes of 64 KB and 256 KB are supported.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)