Setting unit policies – Avago Technologies 3ware SAS 9750-16i4e User Manual
Page 112

Chapter 7. Configuring Units
100
3ware SATA+SAS RAID Controller Card Software User Guide, Version 10.2
To name or rename a unit through 3BM
1
At the main 3BM screen, select the unit by highlighting it and pressing
Enter
.
An asterisk appears in the left-most column to indicate that it is selected.
2
Tab
to the
Maintain Unit
button and press
Enter
.
3
On the pop-up menu, select
Configure
and press
Enter
.
On the Configure Disk Array screen, the
Array Name
field is already
selected.
4
Press
Enter
to open a text box.
5
Type a name for the unit and press
Enter
.
6
Tab
to the
OK
button and press
Enter
to select it. You return to the main
3BM screen.
7
When you are finished making changes, press
F8
to save them and exit
3BM.
Setting Unit Policies
The following polices are set when you create a unit, and can be adjusted later
through settings on the
Management >> Controller Settings
pages of 3DM2
and the Policy Control screen in 3BM. Details about adjusting each policy are
described on the following pages.
•
Write Cache.
Determines whether write cache is enabled for the unit.
When the write cache is enabled, data is stored locally on the controller
before it is written to disk, allowing the computer to continue with its next
task. This provides the most efficient access times for your computer
system. When disabled, the computer will wait for the controller to write
all the data to disk before going on to its next task. For details, see
“Enabling and Disabling the Unit Write Cache” on page 102.
This feature interacts with functionality of the BBU, if you have one, and
with the unit’s StorSave profile. For details, see “Enabling and Disabling
the Unit Write Cache” on page 102.
•
Read Cache
. Determines whether Intelligent or Basic Read Cache is
enabled, or whether Read Cache is disabled. Setting the appropriate type
of Read Cache can improve performance for different types of
applications. For details, see “Working with Read Cache Settings” on
page 104.
•
Auto-Verify.
Determines whether the unit will be automatically verified at
a time determined by the Verify Schedule. Enabling this feature helps
insure that the unit is verified on a regular basis. For details, see
“Enabling or Disabling Auto-Verify for a Unit” on page 107.
- 3ware SAS 9750-24i4e 3ware SAS 9750-4i 3ware SAS 9750-4i4e 3ware SAS 9750-8e 3ware SAS 9750-8i 3ware 8006-2LP 3ware 8006-2LP (Channel) 3ware 9550SXU-4LP 3ware 9550SXU-4LP (Channel) 3ware 9550SXU-8LP 3ware 9550SXU-8LP (Channel) 3ware 9650SE-12ML 3ware 9650SE-12ML (Channel) 3ware 9650SE-16ML 3ware 9650SE-16ML (Channel) 3ware 9650SE-24M8 3ware 9650SE-24M8 (Channel) 3ware 9650SE-2LP 3ware 9650SE-2LP (Channel) 3ware 9650SE-4LPML 3ware 9650SE-4LPML (Channel) 3ware 9650SE-8LPML 3ware 9650SE-8LPML (Channel) 3ware 9690SA-4I 3ware 9690SA-4I (Channel) 3ware 9690SA-4I4E 3ware 9690SA-4I4E (Channel) 3ware 9690SA-8E 3ware 9690SA-8E (Channel) 3ware 9690SA-8I 3ware 9690SA-8I (Channel)