303
4.32 Other G F
unctions
Move rotary axis G15
G15 tilts the rotary axis to the given angle and moves at feed rate to
the programmed position.
Switch off protection zone G60
G60 is used to cancel protection zone monitoring. G60 is programmed
before the traversing command to be monitored or not monitored.
Application example: With G60, you can temporarily deactivate a
programmed monitoring of the protection zone in order to machine a
centric through hole.
X
Z
Y
Z
Y
X
B
Parameters
A, B
Angle – end point of rotary axis
X, Y, Z
End point of principal axis (X diameter value)
U, V, W
End point of secondary axis
Use G15 to move to position, not to machine
Example: G60
. . .
N1 T4 G97 S1000 G95 F0.3 M3
N2 G0 X0 Z5
N3 G60 Q1 [Deactivate the protection zone]
N4 G71 Z-60 K65
N5 G60 Q0
[Activate the protection zone]
. . .
Parameters
Q
Activate/Deactivate
Q=0: Activate protection zone (modal)
Q=1: Deactivate protection zone (modal)
- TNC 122 User Manual (63 pages)
- TNC 122 Technical Manual (70 pages)
- TNC 360 Service Manual (157 pages)
- TNC 416 Technical Manual (510 pages)
- TNC 335 Technical Manual (581 pages)
- TNC 360 User Manual (237 pages)
- TNC 360 ISO-Programmierung (2 pages)
- TNC 415 (280 540) User Manual (227 pages)
- TNC 370D (92 pages)
- TNC 416 (289 pages)
- TNC 415 (280 540) Technical Manual (752 pages)
- TNC 415 (259 96x) Service Manual (195 pages)
- TNC 407 (280 580) User Manual (376 pages)
- iTNC 530 (340 420) Pilot (104 pages)
- TNC 407 (280 580) ISO Programming (333 pages)
- TNC 415 (280 540) Service Manual (252 pages)
- PT 880 Installation (112 pages)
- ND 100 User Manual (116 pages)
- ND 287 User Manual (147 pages)
- ND 280 Quick Start (12 pages)
- ND 200 (156 pages)
- ND 282 (10 pages)
- ND 287 Quick Start (26 pages)
- ND 282 B (39 pages)
- ND 281 A (44 pages)
- ND 281 B v.1 (53 pages)
- ND 281 B v.2 (65 pages)
- ND 221 v.2 (10 pages)
- ND 231 B v.2 (56 pages)
- ND 231 B v.1 (44 pages)
- ND 221 B v.2 (45 pages)
- ND 550 v.2 (8 pages)
- NDP 560 (10 pages)
- ND 523 (93 pages)
- ND 570 (8 pages)
- ND 750 v.2 (46 pages)
- ND 760 v.3 (72 pages)
- ND 770 v.1 (40 pages)
- ND 770 v.3 (41 pages)
- ND 760 E (44 pages)
- IOB 49 (21 pages)
- NDP 960 (68 pages)
- ND 780 Installation (132 pages)
- ND 970 (47 pages)
- ND 1100 Quick Start (36 pages)