Page 50

background image

50

Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012

Chapter 3

FANUC CNC Configuration

3.

Use the arrow keys on the MDI panel to move to the desired
selections.

4.

Prior to setting the parameter, be sure that MDI modes has been

selected by pressing the

button on the CNC main panel.

5.

Enter 1 from the numeric entry, then press INPUT to set the
parameter write enable bit (PWE, 8900#0). This lets you set the
parameters, and configure the CNC for use.

6.

Setting this may cause an alarm to be triggered and displayed.
Cancel the alarm by pressing RESET on the MDI Panel. You will
then have to open the SETTING screen again as described above.

7.

Turn the parameter write enable key switch to the on position.

IMPORTANT This will take affect after the initial program has

been downloaded later in this chapter.