beautypg.com

Import and configure device, And application status logic – Rockwell Automation IASIMP Computer Numerical Control (CNC) Machining Accelerator Toolkit Quick Start User Manual

Page 113

background image

Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012

113

GuardLogix Configuration

Chapter 4

Import and Configure Device and Application Status Logic

In this example, you add the device and application status information rungs to the R02_Monitor routine of your
machine program.

1.

Expand the Tasks folder in the Controller Organizer.

2.

Navigate to and open the R02_Monitor routine of your machine program.

For the CNC Work Cell application example, the R02_Monitor routine within the
P01_CNC_Work_Cell program was opened.

3.

Right-click Rung 13 of the R02_Monitor routine and choose Import Rungs.

IMPORTANT If the DMAT wizard was used to create initial RSLogix project file for your system, select rung 13 and the remaining rungs

up to the end rung. You will be replacing these rungs with the new Device & Application Status logic.