System Commissioning

Chapter 6

The locations and meanings of the status
indicators are indicated below.

Table 7 - Ethernet Module Status Indicators

For further validation of the
Ethernet communication status, the
fast Ethernet card can also be
monitored by using the CNC front
panel display.

1.

From the MDI Panel of the

CNC, press the

key.

Indicator

Status

Description

HER

Off

Normal operation

Solid red

Error detected in the hardware

Flashing red

Error detected in the software

LCOM

Off

Not connected

Solid yellow

Connected

Flashing yellow

Connected, and transmitting / receiving

STATUS

Flashing green

Normal operation

Solid green

Power is on, board is stopped

Off

Power is off

COL

Off

Normal operation

Solid red

Collision occurred, or noise

Flashing red

Collision occurred