Rockwell Automation Publication IASIMP-QS034A-EN-P - October 2012

161

FactoryTalk View ME Configuration

Chapter 5

8.

Expand the HMI
Tags folder and
double-click Tags.

The HMI Tags
editor appears in
the workspace.

9.

Select each of the

xxxAlarmHandshake, xxxAlarmName, and xxxAlarmTrigger tags associated with each of

the alarm triggers that were deleted in the previous steps.

For example, the circled tags are the three tags you would delete if the E3AlarmTrigger had been deleted
previously.

10.

Click

to delete the tags.

11.

Repeat

step 8

step 10

for all unused alarm tags associated with unused alarm triggers.

12.

Click Close to complete tag editing.

TIP

Less editing is required when assigning
HMI alarm tags if you name your
controller shortcut [CLX]. Refer to

Chapter 6

for configuring your

controller shortcuts in RSLinx
Enterprise communication setup.

TIP

Because you used the pre-configured HMI
file instructions, you can skip Design from
an Existing HMI Application File
, and go
directly to

Configure Goto Display Buttons

on Startup Display on page 177

.