beautypg.com

GW Instek APS-1102A User Manual User Manual

Page 64

background image

APS-1102A User Manual

APS-1102A

3-30

b) Using setting range limiter

The APS-1102A internal mode (AC-INT, AC+DC-INT) and internal + external mode (AC-ADD,

AC+DC-ADD) include setting range limiter functions for output voltage and output frequency.

S

ee “5.5.5 Setting range limiter (LIMIT)”, for details.

Table3-13. Voltage and Frequency Setting Range Limiter

Setting

Setting Range

Resolution

Initial Value

Positive voltage
setting limit

100 V range

+0.1 V to +220.0 V

0.1 V

+220.0 V

200 V range

+0.1 V to +440.0 V

0.1 V

+440.0 V

Negative voltage
setting limit

100 V range

220.0 V to

0.1 V

0.1 V

220.0 V

200 V range

440.0 V to

0.1 V

0.1 V

440.0 V

Frequency upper limit setting limit

1.0 Hz to 550.0 Hz

0.1 Hz

550.0 Hz

Frequency lower limit setting limit

1.0 Hz to 550.0 Hz

0.1 Hz

1.0 Hz

Operation steps

The setting range limit is set via the LIMIT screen under the MISC menu

.

1. Press the

or

key to move the cursor to the

icon.

ENTER

CANCEL

Cursor

2. Press the

EN TER

key to display the MISC menu.

Press the

or

to move the cursor key to “LIMIT”.

ENTER

CANCEL