beautypg.com

GW Instek APS-1102A User Manual User Manual

Page 229

background image

6 REMOTE INTERFACE

APS-1102A

6-45

l) Common commands

CLS

This clears the following registers.

Standard event register

Operation event register

Warning event register

Status byte

Error queue

Syntax:

CLS

Parameters:

None

Command example:

CLS

Response format:

None

Response example:

None

ESE

This sets the standard event enable register. The setting ranges from 0 to 255.

Syntax:

ESE

Parameters:

0 to 255

Command example:

ESE 255

Query example:

*ESE?

Response format:

Response example:

255

ESR?

This returns the standard event register value. When *ESR reads the standard event register, all

bits in the event register are cleared to 0. The response ranges from 0 to 255.

Syntax:

ESR?

Parameters:

None

Query example:

ESR?

Response format:

Response example:

128