beautypg.com

4 measure screen – GW Instek APS-1102A User Manual User Manual

Page 157

background image

5 MENUS

APS-1102A

5-23

5.4 MEASURE Screen

The MEASURE screen in the measured value window displays measured values for items selected as

measurement display items (some of which depend on the output mode).

The measured values for output voltage and output current are displayed as values set via “MEASURE”

in the MISC menu.

Table5-18. Display Items in MEASURE Screen

Item

Unit

Select

Measurement

Display

Reference

Voltage RMS value

Vrms

RMS

“5.4.1 Output voltage

measurement

DC voltage value

V

AVG

Maximum
voltage value

Vpk

PEAK

Minimum voltage value

Vpk

PEAK

Current RMS value

Arms

RMS

“5.4.2 Output current

measurement

DC current value

A

AVG

Maximum
current value

Apk

PEAK

Minimum
current value

Apk

PEAK

Current peak value hold

Apk

PEAK

Effective power

W

Always

displayed

“5.4.3 Output power

measurement

Apparent power

VA

Always

displayed

Reactive power

var

Always

displayed

Synchronization
frequency

Hz

During external

synchronization

mode only

“5.4.7 External synchronization

frequency measurement

Load power factor

None

Always

displayed

“5.4.4 Load power factor

measurement

Load crest factor

None

Always

displayed

“5.4.5 Load crest factor

measurement