6 REMOTE INTERFACE

APS-1102A

6-35

MEASure[:SCALar]:VOLTage:HIGH?

This returns the maximum peak value (AC+DC peak value) of the output voltage in Vpk units. For

the 100 V range, the measurement full scale of the maximum peak value of output voltage is ±250

Vpk, and for the 200 V range, it is ±500 Vpk. If the measured value exceeds the measurement

range, 999 Vpk is returned as a measurement error.

Syntax:

MEASure[:SCALar]:VOLTage:HIGH?

Parameters:

None

Query example:

MEAS:VOLT:HIGH?

Response format:

Response example:

100

MEASure[:SCALar]:VOLTage:LOW?

This returns the minimum peak value (AC+DC peak value) of the output voltage in Vpk units. For

the 100 V range, the measurement full scale of the minimum peak value of output voltage is ±250

Vpk, and for the 200 V range, it is ±500 Vpk. If the measured value exceeds the measurement

range,

999 Vpk is returned as a measurement error.

Syntax:

MEASure[:SCALar]:VOLTage:LOW?

Parameters:

None

Query example:

MEAS:VOLT:LOW?

Response format:

Response example:

99

MEASure[:SCALar]:VOLTage:AVErage?

This returns the output voltage average value (AC+DC average value) in V units. For the 100 V

range, the measurement full scale of the average value of output voltage is ±250.0 V, and for the

200 V range, it is ±500.0 V. If the measured value exceeds the measurement range, 999.9 V is

returned as a measurement error.

Syntax:

MEASure[:SCALar]:VOLTage:AVErage?

Parameters:

None

Query example:

MEAS:VOLT:AVE?

Response format:

Response example:

150.2