Detailed command descriptions, 2 detailed command descriptions – GW Instek APS-1102A User Manual User Manual
Page 202
APS-1102A User Manual
APS-1102A
6-18
6.3.2 Detailed command descriptions
The following describes various command functions and syntax.
a) Meanings of symbols
Angle brackets (< >):
Parameter symbols are enclosed in angle brackets. For example,
indicates the digital data format (NR1 type).
A vertical bar ( | )
A parameter is used to alternative parameters. For example, “FIX|STEP”
indicates that either “FIX” or “STEP” can be used as a parameter.
Square brackets ([ ])
An option header is enclosed by square brackets. For example,
“[SOURce:]LIST” indicates that “SOURce:” can be omitted.
Bold (boldface)
Boldface characters are used to emphasize a syntax string when a
command is defined, such as TRIGger:SOURCe
A triangular symbol is used to explicitly indicate that a space exists.
b) Remark
Commands and queries are both included as APS-1102A commands, but for simplicity both are
referred to as commands.
Any command that includes a question mark (?) with a keyword is a query.
Headers are not applied to command reply messages.
c) SOURce subsystem
[SOURce:]CURRent:LIMit:RMS
This sets the upper limit for the output RMS current. The output RMS current limiter setting
ranges from 1.0 A to 10.5 A (for 100 V range) or from 1.0 A to 5.3 A (for 200 V range).
Syntax:
[SOURce:]CURRent:LIMit:RMS
Parameter:
1.0 to 10.5 (1.0 to 5.3)
Command example:
CURR:LIM:RMS 5
Query example:
CURR:LIM:RMS?
Response format:
Response example:
5.0