beautypg.com

Measurement functions, 5 measurement functions – GW Instek APS-1102A User Manual User Manual

Page 274

background image

APS-1102A User Manual

APS-1102A

9-8

9.5 Measurement Functions

a) Output voltage measurement

RMS value:

RMS value of AC+DC

Full scale:

100 V range : 250.0 Vrms

200 V range : 500.0 Vrms

Display resolution:

0.1 Vrms

Measurement accuracy:

at 45 Hz to 65 Hz

100 V range :



(0.5% of rdg + 0.3 Vrms)

200 V range :



(0.5% of rdg + 0.6 Vrms)

at DC, 40 Hz to 550 Hz

100 V range :



(0.7% of rdg + 0.9 Vrms)

200 V range :



(0.7% of rdg + 1.8 Vrms)

(at 23

5°C)

Average value:

Average value of AC+DC (measures DC component)

Full scale:

100 V range :



250.0 V

200 V range :



500.0 V

Display resolution:

0.1 V

Measurement accuracy:

100 V range :



(|0.5% of rdg| + 0.4 V)

200 V range :



(|0.5% of rdg| + 0.8 V)

(at 23

5°C)

Peak value:

Maximum voltage and minimum voltage are displayed

separately

Full scale:

100 V range :



250 Vpk

200 V range :



500 Vpk

Display resolution:

1 Vpk

Measurement accuracy:

100 V range :



(|1.5% of rdg| + 3 Vpk)

200 V range :



(|1.5% of rdg| + 6 Vpk)

(reference value, at 23

5°C, sine wave of which frequency is 45

Hz to 65 Hz)

b) Output current measurement

RMS value:

RMS value of AC+DC

Full scale:

15.00 Arms

Display resolution:

0.01 Arms

Measurement accuracy:

at 45 Hz to 65 Hz

(0.5% of rdg + 0.04 Arms)

at DC, 40 Hz to 550 Hz

(0.7% of rdg + 0.08 Arms)

(at 23

5°C, output current is 5% to 100% of the maximum

current)