beautypg.com

GW Instek APS-1102A User Manual User Manual

Page 270

background image

APS-1102A User Manual

APS-1102A

9-4

h) Maximum output current

100 V range:

10 Arms (AC) / 10 A (DC)

200 V range:

5 Arms (AC) / 5 A (DC)

Note 1:For the AC 100 V input system, the limit on the

maximum output power may cause a reduction in the

maximum output current.

Note 2:If the output voltage is higher than the rated value,

this is limited (lowered) to satisfy the power

capacity.

Note 3:When output frequency is 40 Hz or lower, or it is 400

Hz or higher, the maximum output current may

decrease.

Note 4:The RMS value for AC + DC is within the maximum

output current.

i) Maximum output peak current

100 V range:

40 Apk

200 V range:

20 Apk

Note 1: For the AC 100 V input system, the limit on the

maximum output power may cause a reduction in the

maximum output peak current.

Note 2: The above values are for the capacitor input type

rectifier circuit whose crest factor is 4 or less.

Note 3: If the output voltage is higher than the rated value, the

limit on the maximum output power may reduce the

maximum output peak current.

Note 4: When output frequency is 45 Hz or lower, or it is 65 Hz

or higher, the maximum output peak current may

decrease.

j) Frequency setting (When signal source mode is INT and ADD mode only)

Setting range:

1.0 Hz to 550.0 Hz

Setting resolution:

0.1 Hz

Setting accuracy:

0.01% (23

5°C)

k) Output on phase (When signal source mode is INT and ADD mode only)

Setting range:

0.0

to 359.9

Setting resolution:

0.1

l) Output voltage waveform (When signal source mode is INT and ADD mode only)

Sine wave, square wave, arbitrary waveform (16 types)