6 REMOTE INTERFACE

APS-1102A

6-43

SYSTem:ERRor?

This reads one error from the error queue (FIFO), and clears the read error in the error queue. The

maximum number of errors that can be held in the error queue is 20. If 21 or more errors occur,

[

350, “Too Many Errors”] is inserted as the 20th error.

Syntax:

SYSTem:ERRor?

Parameters:

None

Query example:

SYST:ERR?

Response format:

,

Response example:

0, “No error”

SYSTem:PON[:OUTPut]

This sets the output status at power-on. When the output status is on at power-on, the output turns

on after the start-up and its display finishes.

However, if the system is restarted after a problem has been detected and the system has been

locked, it will be started with output off regardless of this setting.

Syntax:

SYSTem:PON[:OUTPut]

Parameters:

OFF | 0 / ON | 1

Command example:

SYST:PON OFF

Query example:

SYST:PON?

Response format:

Response example:

0

SYSTem:TUNit

This sets the sequence step execution time unit as s or ms.

Syntax:

SYSTem:TUNit

Parameters:

0 (s) / 1 (ms)

Command example:

SYST:TUN 0

Query example:

SYST:TUN?

Response example: