beautypg.com

GW Instek APS-1102A User Manual User Manual

Page 228

background image

APS-1102A User Manual

APS-1102A

6-44

SYSTem:WRELease

This clears a warning. When a warning is cleared, the SET screen is displayed and key input is

enabled. In order for the warning to be cleared, it is necessary that all the factors of the warning

have been removed and it is ready to be cleared.

If no warning has occurred, or if a warning has occurred but the device is not ready to cancel the

warning, [

200, “Execution error”] error occurs.

Syntax:

SYSTem:WRELease

Parameters:

1

Command example:

SYST:WREL 1

Response format:

None

Response example:

None

k) PROGram subsystem

PROGram[:SELected]:EXECute

This controls sequence operations. Control is performed using the STOP (stop), START (run),

HOLD (hold), BRANCH0 (branch 0), or BRANCH1 (branch 1) parameter.

When in AC-EXT, AC-ADD, AC-SYNC, AC+DC-EXT, AC+DC-ADD, or AC+DC-SYNC mode,

sequences cannot be executed. ([3, “Invalid in this mode”] error occurs.)

When output is off, sequence execution is disabled. ([2, “Invalid with output off”] error occurs.)

Syntax:

PROGram[:SELected]:EXECute

Parameters:

STOP / START / HOLD / BRANCH0 / BRANCH1

Command example:

PROG:EXEC START

Response format:

None

Response example:

None