beautypg.com

GW Instek APS-1102A User Manual User Manual

Page 269

background image

9 SPECIFICATIONS

APS-1102A

9-3

e) Output terminals

Terminal block with M4 screws (rear panel)

AC outlet (universal type, front panel)

Note 1: Use the AC outlet for AC (0 V AC to 250 V AC).

When DC is included, use screw terminal block on rear

panel.

Note 2: Output is floating output. The Lo terminal can be

grounded.

f) Rated output voltage

100 V range:

100 Vrms (AC) / 100 V (DC)

200 V range:

200 Vrms (AC) / 200 V (DC)

g) Output voltage settings(When signal source mode is INT mode or ADD mode)

Note: The AC settings (peak value) + DC setting that can be set

are within the voltage setting limit range.

AC

100 V range:

0.0 Vrms to 155.0 Vrms (sine wave, square wave)

0.0 Vp-p to 440.0 Vp-p (arbitrary wave)

200 V range:

0.0 Vrms to 310.0 Vrms (sine wave, square wave)

0.0 Vp-p to 880.0 Vp-p (arbitrary wave)

Setting resolution:

0.1 Vrms (sine wave, square wave)

0.1 Vp-p (arbitrary wave)

Setting accuracy:

100 V range :

(0.5% of set + 0.6 Vrms)

(23

5°C, AC mode, 10 Vrms to 155 Vrms setting, 50 Hz or 60

Hz, sine wave, no load)

200 V range :

(0.5% of set + 1.2 Vrms)

(23

5°C, AC mode, 20 Vrms to 310 Vrms setting, 50 Hz or 60

Hz, sine wave, no load)

DC

100 V range:

220.0 V to +220.0 V

200 V range:

440.0 V to +440.0 V

Setting resolution:

0.1 V

Setting accuracy:

100 V range :

(

0.5 % of set

+ 0.6 V)

(23

5°C, AC+DC mode, output AC voltage setting = 0 V,

220

V to

10 V or +10 V to +220 V setting, no load)

200 V range :

(

0.5 % of set

+ 1.2 V)

(23

5°C, AC+DC mode, output AC voltage setting = 0 V,

440

V to

20 V or +20 V to +440 V setting, no load)