9 SPECIFICATIONS
APS-1102A
9-3
e) Output terminals
Terminal block with M4 screws (rear panel)
AC outlet (universal type, front panel)
Note 1: Use the AC outlet for AC (0 V AC to 250 V AC).
When DC is included, use screw terminal block on rear
panel.
Note 2: Output is floating output. The Lo terminal can be
grounded.
f) Rated output voltage
100 V range:
100 Vrms (AC) / 100 V (DC)
200 V range:
200 Vrms (AC) / 200 V (DC)
g) Output voltage settings(When signal source mode is INT mode or ADD mode)
Note: The AC settings (peak value) + DC setting that can be set
are within the voltage setting limit range.
AC
100 V range:
0.0 Vrms to 155.0 Vrms (sine wave, square wave)
0.0 Vp-p to 440.0 Vp-p (arbitrary wave)
200 V range:
0.0 Vrms to 310.0 Vrms (sine wave, square wave)
0.0 Vp-p to 880.0 Vp-p (arbitrary wave)
Setting resolution:
0.1 Vrms (sine wave, square wave)
0.1 Vp-p (arbitrary wave)
Setting accuracy:
100 V range :
(0.5% of set + 0.6 Vrms)
(23
5°C, AC mode, 10 Vrms to 155 Vrms setting, 50 Hz or 60
Hz, sine wave, no load)
200 V range :
(0.5% of set + 1.2 Vrms)
(23
5°C, AC mode, 20 Vrms to 310 Vrms setting, 50 Hz or 60
Hz, sine wave, no load)
DC
100 V range:
220.0 V to +220.0 V
200 V range:
440.0 V to +440.0 V
Setting resolution:
0.1 V
Setting accuracy:
100 V range :
(
0.5 % of set
+ 0.6 V)
(23
5°C, AC+DC mode, output AC voltage setting = 0 V,
220
V to
10 V or +10 V to +220 V setting, no load)
200 V range :
(
0.5 % of set
+ 1.2 V)
(23
5°C, AC+DC mode, output AC voltage setting = 0 V,
440
V to
20 V or +20 V to +440 V setting, no load)