g) OUTPut subsystem

OUTPut[:STATe]

This controls on/off settings of the output relay.

Syntax:

OUTPut[:STATe]

Parameters:

OFF|0 / ON|1

Command example:

OUTP ON

Query example:

OUTP?

Response format:

Response example:

1

h) INPut subsystem

INPut:GAIN

This sets the external input gain used in the external mode (AC-EXT or AC+DC-EXT) and

internal + external mode (AC-ADD or AC+DC-ADD). For the 100 V range, the external input

gain setting ranges from 0.0 to 220.0 and for the 200 V range, it ranges from 0.0 to 440.0.

When in AC-EXT, AC-ADD, AC+DC-EXT, or AC+DC-ADD mode, the output waveform setting

cannot be made. ([3, “Invalid in this mode”] error occurs.)

Syntax:

INPut:GAIN

Parameters:

0.0 to 220.0 (0.0 to 440.0)

Command example:

INP:GAIN 10.0

Query example:

INP:GAIN?

Response format:

Response example:

10.0