beautypg.com

GW Instek APS-1102A User Manual User Manual

Page 206

background image

APS-1102A User Manual

APS-1102A

6-22

[SOURce:]PHASe:CLOCk

This sets the sync signal source in the external synchronization mode (AC-SYNC or

AC+DC-SYNC). The sync signal source setting is either LINE (line synchronization) or EXT

(external synchronization). However, when output is on, the sync signal source cannot be changed.

([1, “Invalid with output on”] error occurs.)

Unless the mode is AC-SYNC or AC+DC-SYNC mode, the sync signal source setting cannot be

set. ([3, “Invalid in this mode”] error occurs.)

Syntax:

[SOURce:]PHASe:CLOCk

Parameters:

LINE/EXT

Command example:

PHAS:CLOC EXT

Query example:

PHAS:CLOC?

Response format:

Response example:

EXT

[SOURce:]PHASe[:IMMediate]

This sets the phase at the start of output. The phase setting range is 0.0

to 359.9

. However, when

output is on, the phase setting cannot be changed. ([1, “Invalid with output on”] error occurs.)

When in AC-EXT or AC+DC-EXT mode, the phase setting cannot be set. ([3, “Invalid in this

mode”] error occurs.)

Syntax:

[SOURce:]PHASe[:IMMediate]

Parameters:

0.0 to 359.9

Command example:

PHAS 90

Query example:

PHAS?

Response format:

Response example:

90.0

[SOURce:]SEQuence:CONDition?

This returns the sequence status. The response message is 0 (Idle mode), 1 (Run mode), or 2 (Hold

mode).

Syntax:

[SOURce:]SEQuence:CONDition?

Parameters:

None

Query example:

SEQ:COND?

Response format:

Response example:

0