[SOURce:]VOLTage:LIMit:LOW
This sets the lower limit of the output voltage that can be set. However, a value that is equal to or
higher than the currently set cannot be specified. ([5, “Out of Limiter”] error occurs.)
For the 100 V range, the limit value setting ranges from
220.0 to
0.1 V, and for the 200 V range,
it ranges from
440.0 to
0.1 V.
Syntax:
[SOURce:]VOLTage:LIMit:LOW
Parameters:
220.0 to
0.1 (
440.0 to
0.1)
Command example:
VOLT:LIM:LOW
200
Query example:
VOLT:LIM:LOW?
Response format:
Response example:
200.0
[SOURce:]VOLTage:OFFSet[:IMMediate]
This sets the DC voltage when in AC+DC-INT, AC+DC-ADD, or AC+DC-SYNC mode. For the
100 V range, the DC output voltage setting ranges from
220.0 V to 220.0 V, and for the 200 V
range, it range, from
440.0 V to 440.0 V.
The DC output voltage cannot be set unless the mode is AC+DC-INT, AC+DC-ADD, or
AC+DC-SYNC mode. ([3, “Invalid in this mode”] error occurs.)
Syntax:
[SOURce:]VOLTage:OFFSet[:IMMediate]
Parameters:
220.0 to 220.0 (
440.0 to 440.0)
Command example:
VOLT:OFFS 10
Query example:
VOLT:OFFS?
Response format:
Response example:
10.0
[SOURce:]VOLTage:ADJust:OFFSet:AC
This sets the DC offset voltage adjustment value in mV when in AC-INT, AC-EXT, AC-ADD,
AC-SYNC mode. It ranges from
50.0 mV to 50.0 mV. (The setting range is common to 100 V
range and 200 V range.)
The DC offset voltage adjustment value cannot be set unless the mode is AC-INT, AC-EXT,
AC-ADD, AC-SYNC mode. ([3, “Invalid in this mode”] error occurs.)
Syntax:
[SOURce:]VOLTage:OFFSet:AC
Parameters:
50.0 to 50.0
Command example:
VOLT:ADJ:OFFS:AC 10
Query example:
VOLT:ADJ:OFFS:OFFS:AC?
Response format:
Response example:
10.0