6 REMOTE INTERFACE

APS-1102A

6-27

[SOURce:]SEQuence:STEP

Specifies the target step number for sequence editing. The step number specification ranges from 1

to 255.

Syntax:

[SOURce:]SEQuence:STEP

Parameters:

1 to 255

Command example:

SEQ:STEP 1

Query example:

SEQ:STEP?

Response format:

Response example:

1

[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]

AC output voltage is set using the Vrms unit (when the waveform is SIN or SQU) or the Vp-p unit

(when the waveform is ARB). For the 100 V range, output voltage setting ranges from 0.0 Vrms to

155.0 Vrms or from 0.0 Vp-p to 440.0 Vp-p, and for the 200 V range, it ranges from 0.0 Vrms to

310.0 Vrms or from 0.0 Vp-p to 880.0 Vp-p.

When in AC-EXT or AC+DC-EXT mode, the output AC voltage cannot be set or queried. ([3,

“Invalid in this mode”] error occurs.)

Syntax:

[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]

Parameters:

0.0 to 155.0/0.0 to 440.0 (0.0 to 310.0/0.0 to 880.0)

Command example:

VOLT 100

Query example:

VOLT?

Response format:

Response example:

100.0

[SOURce:]VOLTage:LIMit:HIGH

This sets the upper limit of the output voltage that can be set. However, a value that is equal to or

lower than the currently set cannot be specified. ([5, “Out of Limiter”] error occurs.)

For the 100 V range, the limit value setting ranges from 0.1 V to 220.0 V, and for the 200 V range,

it ranges from 0.1 V to 440.0 V.

Syntax:

[SOURce:]VOLTage:LIMit:HIGH

Parameters:

0.1 to 220.0 (0.1 to 440.0)

Command example:

VOLT:LIM:HIGH 200

Query example:

VOLT:LIM:HIGH?

Response format:

Response example:

200.0