beautypg.com

Withstand voltage and insulation resistance, Safety and emc, 14 withstand voltage and insulation resistance – GW Instek APS-1102A User Manual User Manual

Page 282: 15 safety and emc

background image

APS-1102A User Manual

APS-1102A

9-16

9.14 Withstand Voltage and Insulation Resistance

Between input power line vs. output/chassis or input power line/ chassis vs. output

a) Withstand voltage

AC 1500 V, 1 minute

b) Insulation resistance

30 MΩ or higher, 500 V DC

9.15 Safety and EMC

Only Models with a CE Marking on the Rear Panel.

We
GOOD WILL INSTRUMENT CO., LTD.
No. 7-1, Jhongsing Rd, Tucheng Dist., New Taipei City 236. Taiwan.

GOOD WILL INSTRUMENT (SUZHOU) CO., LTD.
No. 69 Lushan Road, Suzhou New District Jiangsu, China.
declare that the below mentioned product
Type of Product: PROGRAMABLE AC/DC POWER SOURCE
Model Number: APS-1102A
is herewith confirmed to comply with the requirements set out in the Council Directive on the
Approximation of the Law of Member States relating to Electromagnetic Compatibility (2004/108/EEC)
and Low Voltage Directive (2006/95/EEC).

For the evaluation regarding the Electromagnetic Compatibility and Low Voltage Directive, the fo llowing
standards were applied:

EMC

EN 61326-1:

Electrical equipment for measurement, control and laboratory use –– EMC
requirements (2006)

Conducted & Radiated Emission
EN 55011: 2009+A1: 2010

Electrostatic Discharge
EN 61000-4-2: 2009

Current Harmonics

EN 61000-3-2: 2006+A1: 2009+A2: 2009

Radiated Immunity
EN 61000-4-3:

2006+A1:

2008+A2: 2010

Voltage Fluctuations
EN 61000-3-3: 2008

Electrical Fast Transients
IEC 61000-4-4: 2004+A1: 2010

-------------------------

Surge Immunity
EN 61000-4-5: 2006

-------------------------

Conducted Susceptibility
EN 61000-4-6: 2009

-------------------------

Power Frequency Magnetic Field
EN 61000-4-8: 2010

-------------------------

Voltage Dip/ Interruption
EN 61000-4-11: 2004


Low Voltage Equipment Directive 2006/95/EEC

Safety Requirements

EN 61010-1: 2010