6 REMOTE INTERFACE

APS-1102A

6-33

MEASure[:SCALar]:FREQuency?

This returns the external sync signal frequency in Hz units. The external sync signal frequency

measurement range is 38.0 Hz to 525.0 Hz. If the measured value exceeds the measurement range,

999.9 Hz is returned as a measurement error.

The frequency measurement can only be performed in external synchronization mode (AC-SYNC

or AC+DC-SYNC). ([3, “Invalid in this mode”] error occurs.)

Syntax:

MEASure[:SCALar]:FREQuency?

Parameters:

None

Query example:

MEAS:FREQ?

Response format:

Response example:

50.4

MEASure[:SCALar]:POWer:AC:APParent?

This returns the apparent power in VA units. The apparent power measurement full scale is 1400

VA. If the measured value exceeds the measurement range, 9999 VA is returned as a measurement

error.

Syntax:

MEASure[:SCALar]:POWer:AC:APParent?

Parameters:

None

Query example:

MEAS:POW:AC:APP?

Response format:

Response example:

367

MEASure[:SCALar]:POWer:AC:PFACtor?

This returns the output power factor. The power factor measurement range is 0.00 to 1.00. When

the measured value exceeds the measurement range, 9.99 is returned as a measurement error.

The power factor is calculated as “effective power/apparent power”.

Syntax:

MEASure[:SCALar]:POWer:AC:PFACtor?

Parameters:

None

Query example:

MEAS:POW:AC:PFAC?

Response format:

Response example:

0.68