7.1 Protection Function

The APS-1102A is equipped with a protection function that monitors the internal status and displays an

error or warning when it detects the following types of abnormalities.

If the beep sound has been set to on, a beep will accompany the displayed error or warning. (A beep

sounds whenever a protection function-related error occurs, regardless of the beep sound setting.)

a) Abnormal output

When output overvoltage or output overcurrent is detected, output will be set to off and the error

message will be displayed.

b) Abnormal power source block

When an internal power source abnormality is detected, output will be set to off and the error or

warning message will be displayed. If it is an error that occurred, all operations will become disabled

except for the power shutdown operation.

c) Abnormal internal control

When an internal control abnormality is detected, output will be set to off and the error or warning

message will be displayed. If it is an error that occurred, all operations will become disabled except for

the power shutdown operation.

d) Abnormal internal temperature

When an internal temperature abnormality is detected, the warning message will be displayed and the

output will be set to off.

See “7.2.2 Protection function-related errors”, for description of error messages.

See “7.2.4 Warning messages”, for description of warning messages.

See “5.6.2 Beep sound”, for description of the beep sound.

The APS-1102A checks an error listed in Table7-1 sequentially from the top and displays only the

error message detected first.